linear-transducer-6.png
Supply
Supply voltage
24 VDC, -20…+10 %
Current consumption no load  
<= 300 mA
Measuring principle  
magnetostrictive
Measuring length, standard  
50…4000 mm, in steps
Resolution  
0.001 mm
Linearity deviation  
typically ± 30 µm
 
± 0.05 mm < 1000 mm
 
± 0.1 mm >= 1000…1500 mm
 
± 0.15 mm > 1500 mm
Reproducibility  
0.005 mm
Hysteresis  
typically < 10 µm
 
< 0.02 mm < 1000 mm
 
< 0.1 mm >= 1000…1500 mm
 
< 0.15 mm > 1500 mm
Characteristics - Validity  
using original TR Magnets
Temperature coefficient  
< 8 µm/°C <= 500 mm
 
< 15 ppm/°C FS > 500 mm
FS:
Full-Scale
Straight line velocity  
no restrictions
Mounting position  
no restrictions
Material - Measuring body  
Cr/Ni - alloy
Rod end mounting  
Option
Magnet  
T4-M33
 
other on request
SERCOS III - Interface
SERCOS III
IEC 61784-2, IEC 61158
Physical Layer
Fast Ethernet, ISO/IEC 8802-3
Device profile
Encoder Profile
Communication cycle
>= 130 µs
Transmission rate
Specific value
100 MBit/s
Parameter/Function, changeable  
Zero adustment
 
Counting direction
Type of parametrization  
programmable
Programming - Tool  
Fieldbus-Device
 
TR-Soft: TRWinProg
Cycle time internal, <= 0.50 m  
0.50 ms
Cycle time internal, <= 1.00 m  
1.00 ms
Cycle time internal, <= 2.00 m  
1.50 ms